Název |
Cena |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Zero-Maintenance Cache Protection
Intelligent Power Management
8 internal ports
MD2 – Low profile form factor
1.2GHz Dual Core RAID on Chip (ROC)
8-Lane PCI-Express bus interface
0, 1, 1E, 5, 5EE, 6, 10, 50, 60, JBOD
Support for Hybrid SSD/HDD RAID 1, 10
512MB DDR2 cache
4GB NAND flash for cache protection
2 SFF-8087 (int.)
Up to 256 SATA or SAS devices using SAS expanders
Adaptec Storage Manager, Copyback Hot Spare management features
RoHS compliant
3 year warranty
|
|
|
LSI BBU MegaRAID SAS 9260 and 9280 Series
|
|
|
|
|
|
|
|
|
|
|
|
1 controller, no cable; Windows, Linux, Netware, Solaris, and SCO; BIOS configuration utility
PCIe x1 host connectivity
Compatibility with SCSI and tape hard drives
Ultra320 SCSI single channel
Top performance with Adaptec Speedflex
Supports up to 15 SCSI bus IDs
Automatic termination
Up to 12 meter cable lengths
Low profile
RoHS compliant
Complete List of Supported Operating Systems
Supported Operating Systems
Microsoft Windows
SuSE Linux
Red Hat Linux
Novell NetWare
SCO OpenServer
SCO UnixWare
Sun Solaris
For a detailed list see ASK Answer ID 15032
Key Differentiators
Industry’s first PCIe x1 Ultra320 SCSI controller that is ideal as a SCSI disk drive and SCSI tape drive connection solution with unparalleled PCIe connectivity and industry standard compatibility.
Customer Needs
Connect SCSI devices to a workstation or server with PCIe slots
System Environment
x86, AMD64 and EM64T system architectures with PCIe host connections
Form Factor
MD2 low-profile
Number of devices
Up to 15 SCSI devices
Bus System Interface Type
PCIe x1
External Connectors
One 68-pin VHDCI
Internal Connectors
One 68-pin Ultra320
Data Transfer Rate
Up to 320 MByte/sec.
Package Contents
O Adaptec 29320LPE Controller with standard bracket
O Replacement low-profile bracket
O One 6-position Ultra320 SCSI LVD cable with terminator (kits only) (2138800-R)
O Quick Install Guide
O CD with drivers and documentation
Warranty
3 years limited warranty, 2 years technical support
Management Ultilities
Adaptec BIOS Configuration Utility
Physical Dimensions
2.54” H x 6.60” L (65mm x 168mm)
Operating Temperature (incl. battery)
0°C to 55°C
Operating Voltage
12V +/-9%, 3.3V +/-9%
Regulatory Certification
FCC, UL, C-tick, CE, VCC
Mean Time Before Failure (MTBF)
1,575,743 hours at 40 degrees C
|
|
|
|
|
|
|
|
|
|
|
|
LSI BBU MegaRAID SAS 9265 and 9285 Series
|
|
|
|
|
|
Benefits
Performance Unified Serial RAID controller supports both SATA and SAS devices. Ideal for bandwidth intensive storage applications; NAS, OLTP servers, web servers, and digital surveillance. Offers Zero-Maintenance Cache Protection and Intelligent Power Management.
Key Differentiators
Zero-Maintenance Cache Protection
Intelligent Power Management
Customer Needs
High I/O transaction and high bandwidth processing.
Form Factor
MD2 Low-Profile
Cache Memory
512MB of DDR2 667MHz cache memory
RAID Levels
RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50, 60 and JBOD
Key RAID Features
• Supports up to 256 SATA or SAS devices using SAS expanders
• RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50, 60 and JBOD
• Quick initialization
• Online Capacity Expansion
• Copyback Hot Spare
• Dynamic caching algorithm
• Native Command Queuing (NCQ)
• Background initialization
• Hot-plug drive support
• RAID Level Migration
• Hot spares – global, dedicated, and pooled
• Automatic/manual rebuild of hot spares
• SES and SAF-TE enclosure management
• Configurable stripe size
• S.M.A.R.T. support
• Multiple arrays per disk drive
• Dynamic sector repair
• Staggered drive spin-up
• Bootable array support
• Optimized Disk Utilization
Bus System Interface Type
8-lane PCIe Gen2
Internal Connectors
2 internal (SFF-8087) Mini SAS
Data Transfer Rate
6 Gb/s per port
Package Contents
• Adaptec RAID 6805 Controller
• Additional low profile vented bracket
• Quick Installation Guide
(English/French/German/Italian/Spanish)
• Software and documentation CDs
SGL/bulk - součástí nejsou kabely!
Warranty
3 years
Management Utilities
Adaptec Storage Manager™ (ASM)
• Java-based GUI Management Utility
• Remote configuration, monitoring & notification
• ASM OS Support: Windows, Linux, SCO, Solaris, FreeBSD
• Microsoft VDS Support
• SNMP, SMTP
• Remote firmware updates
ARCCONF
• Command Line Interface
Adaptec BIOS Configuration Utility (ACU)
• BIOS level configuration utility
• Flashable BIOS support
Physical Size
2.5" H x 6.6" L (64mm x 167mm)
Operating Temperature
0°C to 55°C (with 200 LFM airflow)
Operating Voltage
0.17 amp @ 3.3V
1.25 amp @ 12V measured on PCIe Gen2 systems with 6G drives
Regulatory Certification
CE, FCC, UL, C-tick, VCCI, KCC
Environmental Compliance
RoHS, REACH, WEEE
Mean Time Before Failure (MTBF)
860,953 hours at 40 degree C.
Operating System
Windows 7
Windows Server 2008/2008 R2
Windows Vista
VMware ESX Classic 4.x (vsphere)
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
Sun Solaris 10 x86
FreeBSD
Debian Linux
Ubuntu Linux
Fedora Linux
The latest drivers are available at www.adaptec.com/support.
|
|
|
Benefits
Performance Unified Serial RAID controllers support both SATA and SAS devices. Ideal for bandwidth intensive storage applications; NAS, OLTP servers, web servers, and digital surveillance. Offers Zero-Maintenance Cache Protection and Intelligent Power Management.
Key Differentiators
Zero-Maintenance Cache Protection. Intelligent Power Management.
Customer Needs
High I/O transaction and high bandwidth processing.
Form Factor
MD2 Low-Profile
Cache Memory
512MB of DDR2 667MHz cache memory
RAID Levels
RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50*, 60*, JBOD
(* Expander is necessary)
Key RAID Features
• Supports up to 256 SATA or SAS devices using SAS expanders
• RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50, 60 and JBOD
• Quick initialization
• Online Capacity Expansion
• Copyback Hot Spare
• Dynamic caching algorithm
• Native Command Queuing (NCQ)
• Background initialization
• Hot-plug drive support
• RAID Level Migration
• Hot spares – global, dedicated, and pooled
• Automatic/manual rebuild of hot spares
• SES and SAF-TE enclosure management
• Configurable stripe size
• S.M.A.R.T. support
• Multiple arrays per disk drive
• Dynamic sector repair
• Staggered drive spin-up
• Bootable array support
• Optimized Disk Utilization
Bus System Interface Type
8-lane PCIe Gen2
Internal Connectors
1 internal (SFF-8087) Mini SAS
Data Transfer Rate
6 Gb/s per port
Package Content
• Adaptec RAID 6405 Controller
• Additional low profile vented bracket
• Quick Installation Guide
(English/French/German/Italian/Spanish)
• Software and documentation CDs
SGL/bulk - součástí nejsou kabely!
Warranty
3 years
Management Utilities
Adaptec Storage Manager™ (ASM)
• Java-based GUI Management Utility
• Remote configuration, monitoring & notification
• ASM OS Support: Windows, Linux, SCO, Solaris, FreeBSD
• Microsoft VDS Support
• SNMP, SMTP
• Remote firmware updates
ARCCONF
• Command Line Interface
Adaptec BIOS Configuration Utility (ACU)
• BIOS level configuration utility
• Flashable BIOS support
Physical Size
2.5" H x 6.6" L (64mm x 167mm)
Operating Temperature
0°C to 55°C (with 200 LFM airflow)
Operating Voltage
0.17 amp @ 3.3V
1.25 amp @ 12V measured on PCIe Gen2 systems with 6G drives
Regulatory Certification
CE, FCC, UL, C-tick, VCCI, KCC
Environmental Compliance
RoHS, REACH, WEEE
Mean Time Before Failure (MTBF)
889,115 hours at 40 degree C.
Operating System
Windows 7
Windows Server 2008/2008 R2
Windows Vista
VMware ESX Classic 4.x (vsphere)
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
Sun Solaris 10 x86
FreeBSD
Debian Linux
Ubuntu Linux
Fedora Linux
Adaptec Flash Module 600 (AFM 600)
2269700-R
The latest drivers are available at www.adaptec.com/support.
|
|
|
Benefits
Performance Unified Serial RAID controllers support both SATA and SAS devices. Ideal for bandwidth intensive storage applications; NAS, OLTP servers, web servers, and digital surveillance. Offers Zero-Maintenance Cache Protection and Intelligent Power Management.
Key Differentiators
Zero-Maintenance Cache Protection. Intelligent Power Management.
Customer Needs
High I/O transaction and high bandwidth processing.
Form Factor
MD2 Low-Profile
Cache Memory
512MB of DDR2 667MHz cache memory
RAID Levels
RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50*, 60*, JBOD
(* Expander is necessary)
Key RAID Features
• Supports up to 256 SATA or SAS devices using SAS expanders
• RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50, 60 and JBOD
• Quick initialization
• Online Capacity Expansion
• Copyback Hot Spare
• Dynamic caching algorithm
• Native Command Queuing (NCQ)
• Background initialization
• Hot-plug drive support
• RAID Level Migration
• Hot spares – global, dedicated, and pooled
• Automatic/manual rebuild of hot spares
• SES and SAF-TE enclosure management
• Configurable stripe size
• S.M.A.R.T. support
• Multiple arrays per disk drive
• Dynamic sector repair
• Staggered drive spin-up
• Bootable array support
• Optimized Disk Utilization
Bus System Interface Type
8-lane PCIe Gen2
Internal Connectors
1 internal (SFF-8087) Mini SAS
Data Transfer Rate
6 Gb/s per port
Package Content
• Adaptec RAID 6405 Controller
• Additional low profile vented bracket
• Quick Installation Guide
(English/French/German/Italian/Spanish)
• Software and documentation CDs
KIT - součástí 1x mSAS-4SATA (w/sideband)
Warranty
3 years
Management Utilities
Adaptec Storage Manager™ (ASM)
• Java-based GUI Management Utility
• Remote configuration, monitoring & notification
• ASM OS Support: Windows, Linux, SCO, Solaris, FreeBSD
• Microsoft VDS Support
• SNMP, SMTP
• Remote firmware updates
ARCCONF
• Command Line Interface
Adaptec BIOS Configuration Utility (ACU)
• BIOS level configuration utility
• Flashable BIOS support
Physical Size
2.5" H x 6.6" L (64mm x 167mm)
Operating Temperature
0°C to 55°C (with 200 LFM airflow)
Operating Voltage
0.17 amp @ 3.3V
1.25 amp @ 12V measured on PCIe Gen2 systems with 6G drives
Regulatory Certification
CE, FCC, UL, C-tick, VCCI, KCC
Environmental Compliance
RoHS, REACH, WEEE
Mean Time Before Failure (MTBF)
889,115 hours at 40 degree C.
Operating System
Windows 7
Windows Server 2008/2008 R2
Windows Vista
VMware ESX Classic 4.x (vsphere)
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
Sun Solaris 10 x86
FreeBSD
Debian Linux
Ubuntu Linux
Fedora Linux
Adaptec Flash Module 600 (AFM 600)
2269700-R
The latest drivers are available at www.adaptec.com/support.
|
|
|
Benefits
Performance Unified Serial RAID controller supports both SATA and SAS devices. Ideal for bandwidth intensive storage applications; NAS, OLTP servers, web servers, and digital surveillance. Offers Zero-Maintenance Cache Protection and Intelligent Power Management.
Key Differentiators
Zero-Maintenance Cache Protection
Intelligent Power Management
Customer Needs
High I/O transaction and high bandwidth processing.
Form Factor
MD2 Low-Profile
Cache Memory
512MB of DDR2 667MHz cache memory
RAID Levels
RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50 and 60
Key RAID Features
• Supports up to 256 SATA or SAS devices using SAS expanders
• RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50, 60 and JBOD
• Quick initialization
• Online Capacity Expansion
• Copyback Hot Spare
• Dynamic caching algorithm
• Native Command Queuing (NCQ)
• Background initialization
• Hot-plug drive support
• RAID Level Migration
• Hot spares – global, dedicated, and pooled
• Automatic/manual rebuild of hot spares
• SES and SAF-TE enclosure management
• Configurable stripe size
• S.M.A.R.T. support
• Multiple arrays per disk drive
• Dynamic sector repair
• Staggered drive spin-up
• Bootable array support
• Optimized Disk Utilization
Bus System Interface Type
8-lane PCIe Gen2
External Connectors
1 external (SFF-8088) Mini SAS
Internal Connectors
1 internal (SFF-8087) Mini SAS
Data Transfer Rate
6 Gb/s per port
Package Contents
• Adaptec RAID 6445 Controller
• additional low profile vented bracket
• Quick Installation Guide
(English/French/German/Italian/Spanish)
• Software and documentation CDs
SGL/bulk - součástí nejsou kabely!
Warranty
3 years
Management Utilities
Adaptec Storage Manager™ (ASM)
• Java-based GUI Management Utility
• Remote configuration, monitoring & notification
• ASM OS Support: Windows, Linux, SCO, Solaris, FreeBSD
• Microsoft VDS Support
• SNMP, SMTP
• Remote firmware updates
ARCCONF
• Command Line Interface
Adaptec BIOS Configuration Utility (ACU)
• BIOS level configuration utility
• Flashable BIOS support
Physical Size
2.5" H x 6.6" L (64mm x 167mm)
Operating Temperature
0°C to 55°C (with 200 LFM airflow)
Operating Voltage
0.17 amp @ 3.3V
1.25 amp @ 12V measured on PCIe Gen2 systems with 6G drives
Regulatory Certification
CE, FCC, UL, C-tick, VCCI, KCC
Environmental Compliance
RoHS, REACH, WEEE
Mean Time Before Failure (MTBF)
862,728 hours at 40 degree C
Operating System
Windows 7
Windows Server 2008/2008 R2
Windows Vista
VMware ESX Classic 4.x (vsphere)
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
Sun Solaris 10 x86
FreeBSD
Debian Linux
Ubuntu Linux
Fedora Linux
The latest drivers are available at www.adaptec.com/support.
|
|
|
Benefits
Performance Unified Serial RAID controller supports both SATA and SAS devices. Ideal for bandwidth intensive storage applications; NAS, OLTP servers, web servers, and digital surveillance. Offers Zero-Maintenance Cache Protection and Intelligent Power Management.
Key Differentiators
Zero-Maintenance Cache Protection
Intelligent Power Management
Customer Needs
High I/O transaction and high bandwidth processing.
Form Factor
MD2 Low-Profile
Cache Memory
512MB of DDR2 667MHz cache memory
RAID Levels
RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50, 60 and JBOD
Key RAID Features
• Supports up to 256 SATA or SAS devices using SAS expanders
• RAID levels 0, 1, 1E, 5, 5EE, 6, 10, 50, 60 and JBOD
• Quick initialization
• Online Capacity Expansion
• Copyback Hot Spare
• Dynamic caching algorithm
• Native Command Queuing (NCQ)
• Background initialization
• Hot-plug drive support
• RAID Level Migration
• Hot spares – global, dedicated, and pooled
• Automatic/manual rebuild of hot spares
• SES and SAF-TE enclosure management
• Configurable stripe size
• S.M.A.R.T. support
• Multiple arrays per disk drive
• Dynamic sector repair
• Staggered drive spin-up
• Bootable array support
• Optimized Disk Utilization
Bus System Interface Type
8-lane PCIe Gen2
Internal Connectors
2 internal (SFF-8087) Mini SAS
Data Transfer Rate
6 Gb/s per port
Package Contents
• Adaptec RAID 6805 Controller
• Additional low profile vented bracket
• Quick Installation Guide
(English/French/German/Italian/Spanish)
• Software and documentation CDs
KIT - součástí 2x mSAS-4SATA (w/sideband)
Warranty
3 years
Management Utilities
Adaptec Storage Manager™ (ASM)
• Java-based GUI Management Utility
• Remote configuration, monitoring & notification
• ASM OS Support: Windows, Linux, SCO, Solaris, FreeBSD
• Microsoft VDS Support
• SNMP, SMTP
• Remote firmware updates
ARCCONF
• Command Line Interface
Adaptec BIOS Configuration Utility (ACU)
• BIOS level configuration utility
• Flashable BIOS support
Physical Size
2.5" H x 6.6" L (64mm x 167mm)
Operating Temperature
0°C to 55°C (with 200 LFM airflow)
Operating Voltage
0.17 amp @ 3.3V
1.25 amp @ 12V measured on PCIe Gen2 systems with 6G drives
Regulatory Certification
CE, FCC, UL, C-tick, VCCI, KCC
Environmental Compliance
RoHS, REACH, WEEE
Mean Time Before Failure (MTBF)
860,953 hours at 40 degree C.
Operating System
Windows 7
Windows Server 2008/2008 R2
Windows Vista
VMware ESX Classic 4.x (vsphere)
Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
Sun Solaris 10 x86
FreeBSD
Debian Linux
Ubuntu Linux
Fedora Linux
The latest drivers are available at www.adaptec.com/support.
|
|
|
The QLogic 8Gb FC Single-port and Dual-port HBAs have the following features:
Function at 8/4/2 Gbps (auto-negotiation)
Persistent binding
LUN masking
2,048 concurrent logins
PCI Express 2.0 x8 compliance, backwards compatibility with PCI-e 1.0a
One (for Single-port) and two (for Dual-port) SFP+ with LC-style connectors
Standard PCI Express card with low profile MD2 form factor
Support for both standard and low-profile PCI-E slots
The QLogic 8Gb FC Single-port and Dual-port HBAs have the following specifications:
Data rate: 1600 MBps full duplex per port
Performance: up to 200,000 IOPS per port
Boot support: BIOS, FCode, UEFI, EFI
Protocols: FCP-3-SCSI; FC-Tape (FCP-2)
Standard supported: Enhanced Authentication (FC-SP), Data Integrity (T10) and Network isolation (NPIV)
http://www.redbooks.ibm.com/abstracts/tips0721.html?Open
|
|